Arista CI Workshop

This workshop will leverage open-source tools to build a network CI pipeline for configuration development, deployment, documentation, and validation. In addition, the open-source tooling enables us to manage our network environment as code.

This section will cover the following:

  • Arista Validated Designs (AVD) Ansible Collection
  • Network Data Models
  • Initial Deployment (Day 0 Provisioning)
  • Ongoing Operations (Day 2 and Beyond)
  • Validation and Troubleshooting

Each attendee will receive a dedicated virtual lab environment with Git, VS Code, and Ansible installed and ready to use.

Attendees will need the following:

Lab Topology Overview

Throughout this section, we will use the following dual data center topology. Click on the image to zoom in for details.

Dual DC Topology

Basic EOS Switch Configuration

Basic connectivity between the Ansible controller host and the switches must be established before Ansible can be used to deploy configurations. The following should be configured on all switches:

  • Switch Hostname
  • IP enabled interface
  • Username and Password defined
  • Management eAPI enabled
Info

In the ATD environment, cEOS virtual switches use Management0 in the default VRF. When using actual hardware or vEOS switches, Management1 is used. The included basic switch configurations may need to be adjusted for your environment.

Below is an example basic configuration file for s1-spine1:

!
no aaa root
!
username admin privilege 15 role network-admin secret sha512 $6$eucN5ngreuExDgwS$xnD7T8jO..GBDX0DUlp.hn.W7yW94xTjSanqgaQGBzPIhDAsyAl9N4oScHvOMvf07uVBFI4mKMxwdVEUVKgY/.
!
hostname s1-spine1
!
management api http-commands
   no shutdown
!
interface Management0
   ip address 192.168.0.10/24
!
ip routing
!
ip route vrf MGMT 0.0.0.0/0 192.168.0.1
!

Ansible Inventory

Our lab L2LS topology contains two sites, Site 1 and Site 2. We need to create the Ansible inventory for each site. We have created two separate directories for each site under the sites sub-directory in our repo.

├── sites/
  ├── site_1/
  ├── site_2/

The following is a graphical representation of the Ansible inventory groups and naming scheme used for Site 1 in this example. This is replicated for Site 2.

Ansible Groups

AVD Fabric Variables

To apply AVD variables to the nodes in the fabric, we make use of Ansible group_vars. How and where you define the variables is your choice. The group_vars table below is one example of AVD fabric variables for Site 1.

group_vars/ Description
SITE1_FABRIC.yml Fabric, Topology, and Device settings
SITE1_SPINES.yml Device type for Spines
SITE1_LEAFS.yml Device type for Leafs
SITE1_NETWORK_SERVICES.yml VLANs, VRFs, SVIs
SITE1_NETWORK_PORTS.yml Port Profiles and Connected Endpoint settings

Each group_vars file is listed in the following tabs.

At the Fabric level (SITE1_FABRIC), the following variables are defined in group_vars/SITE1_FABRIC.yml. The fabric name, design type (l2ls), node type defaults, interface links, and core interface P2P links are defined at this level. Other variables you must supply include:

  • spanning_tree_mode
  • spanning_tree_priority
  • mlag_peer_ipv4_pool

The l3spine node will need these additional variables set.

  • loopback_ipv4_pool
  • mlag_peer_l3_ipv4_pool
  • virtual_router_mac_address

Variables applied under the node key type (l3spine/leaf) defaults section are inherited by nodes under each type. These variables may be overwritten under the node itself.

The spine interface used by a particular leaf is defined from the leaf's perspective with a variable called uplink_switch_interfaces. For example, s1-leaf1 has a unique variable uplink_switch_interfaces: [Ethernet2, Ethernet2] defined. This means that s1-leaf1 is connected to s1-spine1 Ethernet2 and s1-spine2 Ethernet2, respectively.

---
fabric_name: SITE1_FABRIC

# Set Design Type to L2ls
design:
  type: l2ls

# Repeat MLAG addressing between pairs
fabric_ip_addressing:
  mlag:
    algorithm: same_subnet

# Spine Switches
l3spine:
  defaults:
    platform: cEOS
    spanning_tree_mode: mstp
    spanning_tree_priority: 4096
    loopback_ipv4_pool: 10.1.252.0/24
    mlag_peer_ipv4_pool: 10.1.253.0/31
    mlag_peer_l3_ipv4_pool: 10.1.253.2/31
    virtual_router_mac_address: 00:1c:73:00:dc:01
    mlag_interfaces: [ Ethernet1, Ethernet6 ]
  node_groups:
    - group: SPINES
      nodes:
        - name: s1-spine1
          id: 1
          mgmt_ip: 192.168.0.10/24
        - name: s1-spine2
          id: 2
          mgmt_ip: 192.168.0.11/24

# Leaf Switches
leaf:
  defaults:
    platform: cEOS
    mlag_peer_ipv4_pool: 10.1.253.0/31
    spanning_tree_mode: mstp
    spanning_tree_priority: 16384
    uplink_switches: [ s1-spine1, s1-spine2 ]
    uplink_interfaces: [ Ethernet2, Ethernet3 ]
    mlag_interfaces: [ Ethernet1, Ethernet6 ]
  node_groups:
    - group: RACK1
      filter:
        tags: [ "Web" ]
      nodes:
        - name: s1-leaf1
          id: 1
          mgmt_ip: 192.168.0.12/24
          uplink_switch_interfaces: [ Ethernet2, Ethernet2 ]
        - name: s1-leaf2
          id: 2
          mgmt_ip: 192.168.0.13/24
          uplink_switch_interfaces: [ Ethernet3, Ethernet3 ]
    - group: RACK2
      filter:
        tags: [ "App" ]
      nodes:
        - name: s1-leaf3
          id: 3
          mgmt_ip: 192.168.0.14/24
          uplink_switch_interfaces: [ Ethernet4, Ethernet4 ]
        - name: s1-leaf4
          id: 4
          mgmt_ip: 192.168.0.15/24
          uplink_switch_interfaces: [ Ethernet5, Ethernet5 ]

##################################################################
# Underlay Routing Protocol - ran on Spines
##################################################################

underlay_routing_protocol: OSPF

##################################################################
# WAN/Core Edge Links
##################################################################

core_interfaces:
  p2p_links:
    - ip: [ 10.0.0.29/31, 10.0.0.28/31 ]
      nodes: [ s1-spine1, WANCORE ]
      interfaces: [ Ethernet7, Ethernet2 ]
      include_in_underlay_protocol: true
    - ip: [ 10.0.0.33/31, 10.0.0.32/31 ]
      nodes: [ s1-spine1, WANCORE ]
      interfaces: [ Ethernet8, Ethernet2 ]
      include_in_underlay_protocol: true
    - ip: [ 10.0.0.31/31, 10.0.0.30/31 ]
      nodes: [ s1-spine2, WANCORE ]
      interfaces: [ Ethernet7, Ethernet2 ]
      include_in_underlay_protocol: true
    - ip: [ 10.0.0.35/31, 10.0.0.34/31 ]
      nodes: [ s1-spine2, WANCORE ]
      interfaces: [ Ethernet8, Ethernet2 ]
      include_in_underlay_protocol: true

In an L2LS design, there are two types of spine nodes: spine and l3spine. In AVD, the node type defines the functionality and the EOS CLI configuration to be generated. For our L2LS topology, we will use node type l3spine to include SVI functionality.

---
type: l3spine

In an L2LS design, we have one type of leaf node: leaf. This will provide L2 functionality to the leaf nodes.

---
type: leaf

You add VLANs to the Fabric by updating the group_vars/SITE1_NETWORK_SERVICES.yml. Each VLAN will be given a name and a list of tags. The tags filter the VLAN to specific Leaf Pairs. These variables are applied to spine and leaf nodes since they are a part of this nested group.

---
tenants:
  - name: MY_FABRIC
    vrfs:
      - name: default
        svis:
          - id: 10
            name: 'Ten'
            tags: [ "Web" ]
            enabled: true
            ip_virtual_router_addresses:
              - 10.10.10.1
            nodes:
              - node: s1-spine1
                ip_address: 10.10.10.2/24
              - node: s1-spine2
                ip_address: 10.10.10.3/24
          - id: 20
            name: 'Twenty'
            tags: [ "App" ]
            enabled: true
            ip_virtual_router_addresses:
              - 10.20.20.1
            nodes:
              - node: s1-spine1
                ip_address: 10.20.20.2/24
              - node: s1-spine2
                ip_address: 10.20.20.3/24

Our fabric would only be complete by connecting some devices to it. We define connected endpoints and port profiles in group_vars/SITE1_NETWORKS_PORTS.yml. Each endpoint adapter defines which switch port and port profile to use. Our lab has two hosts connected to the site 1 fabric. The connected endpoints keys are used for logical separation and apply to interface descriptions. These variables are applied to the spine and leaf nodes since they are a part of this nested inventory group.

---
port_profiles:

  - profile: PP-VLAN10
    mode: "access"
    vlans: "10"
    spanning_tree_portfast: edge
  - profile: PP-VLAN20
    mode: "access"
    vlans: "20"
    spanning_tree_portfast: edge

###########################################################
# ---------------- Endpoint Connectivity ---------------- #
###########################################################

servers:

# --------------------------------------------------------#
# Site1 RACK1 Endpoints
# --------------------------------------------------------#

  - name: s1-host1                                      # Server name
    rack: RACK1                                         # Informational RACK (optional)
    adapters:
      - endpoint_ports: [ eth1, eth2 ]                  # Server port to connect (optional)
        switch_ports: [ Ethernet4, Ethernet4 ]          # Switch port to connect server (required)
        switches: [ s1-leaf1, s1-leaf2 ]                # Switch to connect server (required)
        profile: PP-VLAN10                              # Port profile to apply (required)
        port_channel:
          mode: active

# --------------------------------------------------------#
# Site1 RACK2 Endpoints
# --------------------------------------------------------#

  - name: s1-host2                                      # Server name
    rack: RACK2                                         # Informational RACK (optional)
    adapters:
      - endpoint_ports: [ eth1, eth2 ]                  # Server port to connect (optional)
        switch_ports: [ Ethernet4, Ethernet4 ]          # Switch port to connect server (required)
        switches: [ s1-leaf3, s1-leaf4 ]                # Switch to connect server (required)
        profile: PP-VLAN20                              # Port profile to apply (required)
        port_channel:
          mode: active

Global Variables

In a multi-site environment, some variables must be applied to all sites. They include AAA, Local Users, NTP, Syslog, DNS, and TerminAttr. Instead of updating these same variables in multiple inventory group_vars, we can use a single global variable file and import the variables at playbook runtime. This allows us to make a single change applied to all sites.

For example, in our lab, we use a global variable file global_vars/global_dc-vars.yml.

AVD provides a global_vars plugin that enables the use of global variables.

The global_vars plugin must be enabled in the ansible.cfg file as shown below:

#enable global vars
vars_plugins_enabled = arista.avd.global_vars, host_group_vars

#define global vars path
[vars_global_vars]
paths = ../../global_vars
Info

If a folder is used as in the example above, all files in the folder will be parsed in alphabetical order.

Example Global Vars File

global_vars/global_dc_vars.yml
---

# Credentials for CVP and EOS Switches
ansible_user: arista
ansible_password: "{{ lookup('env', 'LABPASSPHRASE') }}"
ansible_network_os: arista.eos.eos
# Configure privilege escalation
ansible_become: true
ansible_become_method: enable
# HTTPAPI configuration
ansible_connection: httpapi
ansible_httpapi_port: 443
ansible_httpapi_use_ssl: true
ansible_httpapi_validate_certs: false
ansible_python_interpreter: $(which python3)
avd_data_conversion_mode: error
avd_data_validation_mode: error

# Local Users
local_users:
  - name: arista
    privilege: 15
    role: network-admin
    sha512_password: "{{ ansible_password | password_hash('sha512', salt='arista') }}"

# AAA
aaa_authorization:
  exec:
    default: local

# OOB Management network default gateway.
mgmt_gateway: 192.168.0.1
mgmt_interface: Management0
mgmt_interface_vrf: default

# NTP Servers IP or DNS name, first NTP server will be preferred, and sourced from Management VRF
ntp:
  servers:
    - name: 192.168.0.1
      iburst: true
      local_interface: Management0

# Domain/DNS
dns_domain: atd.lab

# TerminAttr
daemon_terminattr:
  # Address of the gRPC server on CloudVision
  # TCP 9910 is used on on-prem
  # TCP 443 is used on CV as a Service
  cvaddrs: # For single cluster
    - 192.168.0.5:9910
  # Authentication scheme used to connect to CloudVision
  cvauth:
    method: token
    token_file: "/tmp/token"
  # Exclude paths from Sysdb on the ingest side
  ingestexclude: /Sysdb/cell/1/agent,/Sysdb/cell/2/agent
  # Exclude paths from the shared memory table
  smashexcludes: ale,flexCounter,hardware,kni,pulse,strata

# Point to Point Links MTU Override for Lab
p2p_uplinks_mtu: 1500

# CVP node variables
cv_collection: v3
execute_tasks: true

Data Models

AVD provides a network-wide data model and is typically broken into multiple group_vars files to simplify and categorize variables with their respective functions. We break the data model into three categories: topology, services, and ports.

Fabric Topology

The physical fabric topology is defined by providing interface links between the spine and leaf nodes. The group_vars/SITE1_FABRIC.yml file defines this portion of the data model. In our lab, the spines provide layer 3 routing of SVIs and P2P links using a node type called l3spines. The leaf nodes are purely layer 2 and use node type leaf. An AVD L2LS design type provides three node type keys: l3 spine, spine, and leaf. AVD Node Type documentation can be found here.

Spine and Leaf Nodes

The example data model below defines each site's spine and leaf nodes for each site. Refer to the inline comments for variable definitions. Under each node_type_key you have key/value pairs for defaults, node_groups, and nodes. Note that key/value pairs may be overwritten with the following descending order of precedence. The key/value closest to the node will be used.

  1. defaults
  2. node_groups
  3. nodes
################################
# Spine Switches
################################

# node_type_key for providing L3 services
l3spine:
  # default key/values for all l3spine nodes
  defaults:
    # Platform dependent default settings for mlag timers, tcam profiles, LANZ, management interface
    platform: cEOS
    # Spanning Tree
    spanning_tree_mode: mstp
    spanning_tree_priority: 4096
    # Loopback0 pool, used in conjunction with value of `id:` under each node
    loopback_ipv4_pool: 10.1.252.0/24
    # IP Pool for MLAG peer link
    mlag_peer_ipv4_pool: 10.1.253.0/31
    # IP Pool for L3 peering over the MLAG peer link
    mlag_peer_l3_ipv4_pool: 10.1.253.2/31
    # Virtual MAC address used in vARP
    virtual_router_mac_address: 00:1c:73:00:dc:01
    # Default MLAG interfaces between spine nodes
    mlag_interfaces: [ Ethernet1, Ethernet6 ]
  # keyword for node groups, two nodes within a node group will form an MLAG pair
  node_groups:
    # User-defined node group name
    - group: SPINES
      # key word for nodes
      nodes:
        - name: s1-spine1
          # unique identifier used for IP address calculations
          id: 1
          # Management address assigned to the defined management interface
          mgmt_ip: 192.168.0.10/24
        - name: s1-spine2
          id: 2
          mgmt_ip: 192.168.0.11/24

################################
# Leaf Switches
################################
leaf:
  defaults:
    platform: cEOS
    mlag_peer_ipv4_pool: 10.1.253.0/31
    spanning_tree_mode: mstp
    spanning_tree_priority: 16384
    # Default uplink switches from leaf perspective
    uplink_switches: [ s1-spine1, s1-spine2 ]
    # Default uplink interfaces on leaf nodes connecting to the spines
    uplink_interfaces: [ Ethernet2, Ethernet3 ]
    # Default leaf MLAG interfaces
    mlag_interfaces: [ Ethernet1, Ethernet6 ]
  node_groups:
    # User-defined node group name
    - group: RACK1
      # Filter which Vlans will be applied to the node_group, comma-separated tags supported
      # Tags for each Vlan are defined in the SITE1_FABRIC_SERVICES.yml
      filter:
        tags: [ "Web" ]
      nodes:
        - name: s1-leaf1
          id: 1
          mgmt_ip: 192.168.0.12/24
          # Define which interface is configured on the uplink switch
          # In this example s1-leaf1 connects to [ s1-spine1, s1-spine2 ]
          # on the following ports. This will be unique to each leaf
          uplink_switch_interfaces: [ Ethernet2, Ethernet2 ]
        - name: s1-leaf2
          id: 2
          mgmt_ip: 192.168.0.13/24
          uplink_switch_interfaces: [ Ethernet3, Ethernet3 ]
    - group: RACK2
      filter:
        tags: [ "App" ]
      nodes:
        - name: s1-leaf3
          id: 3
          mgmt_ip: 192.168.0.14/24
          uplink_switch_interfaces: [ Ethernet4, Ethernet4 ]
        - name: s1-leaf4
          id: 4
          mgmt_ip: 192.168.0.15/24
          uplink_switch_interfaces: [ Ethernet5, Ethernet5 ]

Core Interfaces

Inside the same group_vars file, we define how each site is linked to the Core IP Network using point-to-point L3 links on the spine nodes. In our example, OSPF will be used to share routes between sites across the IP Network. The core_interfaces data model for Site 1 follows.

core_interfaces:
  p2p_links:
    # s1-spine1 Ethernet7 to WANCORE
    - ip: [ 10.0.0.29/31, 10.0.0.28/31 ]
      nodes: [ s1-spine1, WANCORE ]
      interfaces: [ Ethernet7, Ethernet2 ]
      include_in_underlay_protocol: true

    # s1-spine1 Ethernet8 to WANCORE
    - ip: [ 10.0.0.33/31, 10.0.0.32/31 ]
      nodes: [ s1-spine1, WANCORE ]
      interfaces: [ Ethernet8, Ethernet2 ]
      include_in_underlay_protocol: true

    # s1-spine2 Ethernet7 to WANCORE
    - ip: [ 10.0.0.31/31, 10.0.0.30/31 ]
      nodes: [ s1-spine2, WANCORE ]
      interfaces: [ Ethernet7, Ethernet2 ]
      include_in_underlay_protocol: true

    # s1-spine2 Ethernet8 to WANCORE
    - ip: [ 10.0.0.35/31, 10.0.0.34/31 ]
      nodes: [ s1-spine2, WANCORE ]
      interfaces: [ Ethernet8, Ethernet2 ]
      include_in_underlay_protocol: true

The following diagram shows the P2P links to the IP Network from all four spine nodes. The WAN IP Network is pre-configured in our lab with /31's running OSPF in area 0.0.0.0. The core_interfaces for the spines in Site 1 and Site 2 are configured and deployed with AVD.

Core Interfaces

Fabric Services

Fabric Services, such as VLANs, SVIs, and VRFs, are defined in this section. The following Site 1 example defines VLANs and SVIs for VLANs 10 and 20 in the default VRF. Additional VRF definitions can also be applied.

---
tenants:
  # User-defined Tenant/Fabric name
  - name: MY_FABRIC
    # key-word
    vrfs:
      # Default VRF
      - name: default
        # key-word
        svis:
          # Vlan ID
          - id: 10
            # Vlan Name
            name: 'Ten'
            # Tag assigned to Vlan. Used as a filter by each node_group
            tags: [ "Web" ]
            enabled: true
            # SVI Virtual ARP address, used along with pre-defined virtual_router_mac_address
            ip_virtual_router_addresses:
              - 10.10.10.1
            # Which nodes to apply physical SVI address
            nodes:
              - node: s1-spine1
                ip_address: 10.10.10.2/24
              - node: s1-spine2
                ip_address: 10.10.10.3/24
          - id: 20
            name: 'Twenty'
            tags: [ "App" ]
            enabled: true
            ip_virtual_router_addresses:
              - 10.20.20.1
            nodes:
              - node: s1-spine1
                ip_address: 10.20.20.2/24
              - node: s1-spine2
                ip_address: 10.20.20.3/24

Fabric Ports

The Fabric must define ports for southbound interfaces toward connected endpoints such as servers, appliances, firewalls, and other networking devices in the data center. This section uses port profiles and connected endpoints called servers. Documentation for port_profiles and connected endpoints are available to see all the options available.

The following data model defined two port profiles: PP-VLAN10 and PP-VLAN20. They define an access port profile for VLAN 10 and 20, respectively. In addition, two server endpoints (s1-host1 and s1-host2) are created to use these port profiles. There are optional and required fields. The optional fields are used for port descriptions in the EOS intended configurations.

---
port_profiles:

  - profile: PP-VLAN10
    mode: "access"
    vlans: "10"
    spanning_tree_portfast: edge
  - profile: PP-VLAN20
    mode: "access"
    vlans: "20"
    spanning_tree_portfast: edge

###########################################################
# ---------------- Endpoint Connectivity ---------------- #
###########################################################

servers:

# --------------------------------------------------------#
# Site1 RACK1 Endpoints
# --------------------------------------------------------#

  - name: s1-host1                                      # Server name
    rack: RACK1                                         # Informational RACK (optional)
    adapters:
      - endpoint_ports: [ eth1, eth2 ]                  # Server port to connect (optional)
        switch_ports: [ Ethernet4, Ethernet4 ]          # Switch port to connect server (required)
        switches: [ s1-leaf1, s1-leaf2 ]                # Switch to connect server (required)
        profile: PP-VLAN10                              # Port profile to apply (required)
        port_channel:
          mode: active

# --------------------------------------------------------#
# Site1 RACK2 Endpoints
# --------------------------------------------------------#

  - name: s1-host2                                      # Server name
    rack: RACK2                                         # Informational RACK (optional)
    adapters:
      - endpoint_ports: [ eth1, eth2 ]                  # Server port to connect (optional)
        switch_ports: [ Ethernet4, Ethernet4 ]          # Switch port to connect server (required)
        switches: [ s1-leaf3, s1-leaf4 ]                # Switch to connect server (required)
        profile: PP-VLAN20                              # Port profile to apply (required)
        port_channel:
          mode: active

The Playbooks

Two playbooks, build.yml and deploy.yml are used in our lab. Expand the tabs below to reveal the content.

build.yml Playbook
---
- name: Build Switch configuration
  hosts: "{{ target_hosts }}"
  gather_facts: false

  tasks:

    - name: Generate Structured Variables per Device
      import_role:
        name: arista.avd.eos_designs

    - name: Generate Intended Config and Documentation
      import_role:
        name: arista.avd.eos_cli_config_gen
deploy.yml Playbook
---
- name: Deploy Switch configuration
  hosts: "{{ target_hosts }}"
  gather_facts: false

  tasks:

    - name: Deploy Configuration to Device
      import_role:
        name: arista.avd.eos_config_deploy_eapi

To make our lives easier, we use a Makefile to create aliases to run the playbooks and provide the needed options. This eliminates mistakes and typing long commands.

Makefile
.PHONY: help
help: ## Display help message
    @grep -E '^[0-9a-zA-Z_-]+\.*[0-9a-zA-Z_-]+:.*?## .*$$' $(MAKEFILE_LIST) | sort | awk 'BEGIN {FS = ":.*?## "}; {printf "\033[36m%-30s\033[0m %s\n", $$1, $$2}'

########################################################
# Site 1
########################################################

.PHONY: build-site-1
build-site-1: ## Build Configs
    ansible-playbook playbooks/build.yml -i sites/site_1/inventory.yml -e "target_hosts=SITE1_FABRIC"
# ansible-playbook playbooks/build.yml -i sites/site_1/inventory.yml -e "target_hosts=SITE1_FABRIC" -e "@global_vars/global_dc_vars.yml"

.PHONY: deploy-site-1
deploy-site-1: ## Deploy Configs via eAPI
    ansible-playbook playbooks/deploy.yml -i sites/site_1/inventory.yml -e "target_hosts=SITE1_FABRIC"

########################################################
# Site 2
########################################################

.PHONY: build-site-2
build-site-2: ## Build Configs
    ansible-playbook playbooks/build.yml -i sites/site_2/inventory.yml -e "target_hosts=SITE2_FABRIC"

.PHONY: deploy-site-2
deploy-site-2: ## Deploy Configs via eAPI
    ansible-playbook playbooks/deploy.yml -i sites/site_2/inventory.yml -e "target_hosts=SITE2_FABRIC"

For example, if we wanted to run a playbook to build configs for Site 1, we could enter the following command.

ansible-playbook playbooks/build.yml -i sites/site_1/inventory.yml -e "target_hosts=SITE1_FABRIC"

Thankfully, a convenient way to simplify the above command is with a Makefile entry like the one below.

.PHONY: build-site-1
build-site-1: ## Build Configs
  ansible-playbook playbooks/build.yml -i sites/site_1/inventory.yml -e "target_hosts=SITE1_FABRIC"

Now, you can type the following to issue the same ansible-playbook command.

make build-site-1

In the upcoming lab, we will use the following make commands several times. First, review the above Makefile to see what each entry does. Then, try building some custom entries.

Build configurations

# Build configs for Site 1
make build-site-1

# Build configs for Site 2
make build-site-2

Deploy configurations

# Deploy configs for Site 1
make deploy-site-1

# Deploy configs for Site 2
make deploy-site-2

Next Steps

Continue to Lab Guide